Analisis Performansi Turbin Angin Poros Horisontal Model Double Rotor Contra Rotating dengan Posisi Rotor Saling Berhimpitan

  • Fredrikus M. Bere(1)
  • Verdy Ariyanto Koehuan(2)
    Jurusan Teknik Mesin, Fakultas Sains dan Teknik, Universitas Nusa Cendana http://orcid.org/0000-0003-1204-8776
  • Jahirwan Ut Jasron(3)
    Jurusan Teknik Mesin, Fakultas Sains dan Teknik, Universitas Nusa Cendana https://orcid.org/0000-0002-4961-5300
  • (*) Corresponding Author
Keywords: Contra rotating, Wind turbine, Blade angle, Power coefficient

Abstract

Abstract

The contra rotating wind turbine is a horizontal axis turbine which has two shaft rotating in opposite directions on the same axis, and it can work at low wind speeds. In general, the performance of the wind turbine are affected by several factors, which is the aerodynamics shape of turbine, the numbers of blade and the selection angle of blade. In this study, conducted by determining the variation of angle on the blade and the blade angle used in the study is 0o, 5o, and 10o, on the two rotors with diameter of front rotor is 0.50 meters and the rear rotor is 0.30 meters, with the position of the rotor blade is coincident with each other. The purpose of this study, is to determine the effect of blade angle variation on the turbine rotation (rpm), torque (T), the power coefficient (Cp), torque coefficient (Cq) and the efficient of the turbine at any wind speeds variations. On the graph relation of blade angle on the shaft rotation, turbine rotation riding known to along with the addition of angle of the blade. The speed of wind is very affect on the output or mechanical power and power coefficient. On the blade angle 0o with wind speed at 4.03 m/s, the power can be generate is 3.013 Watt, and for blade angle 10o with wind speeds 6.08 m/s, the power can be generate is 8.217 Watt. The lowest rotation of rotor without loading is 702 rpm at the wind speeds on 4.03 m/s with angle of blade 0o, the highest rotation of rotor is 1484 rpm on the wind speeds 6.08 m/s with angle of blade 10o. From the graph of analysis data can be seen , with change of angle blade on wind turbine horizontal shaft contra rotating models, power coefficient (Cp) generated of turbine activity increases with increased of angle, with Cp maks 0.718 for angle 10o, maximum efficiency an generated reach out 71.8%.

Downloads

Download data is not yet available.

References

Andrzej Piegat. 2005. A New Definition Of The Fuzzy Set. Faculty Of Computer Science And Information Systems Technical University Of Szczecin Ul. Zołnierska, Poland.

Chantharasenawong C., Suwantragul B. and Ruangwiset A. (2008). Axial Momentum Theory for Turbines with Co-axial Counter Rotating Rotors, Commemorative International Conference of the Occasion of the 4th Cycle Anniversary of KMUTT Sustainable Development to Save the Earth: 11-13 December 2008, Bangkok, Thailand

Betz A 1920 Zeittschrift für das gesamte turbinewessen 307-309.

Daryanto, Y. 2007. Kajian Potensi Angin untuk Pembangkit Listrik Tenaga Bayu. Balai PPTAGG: Yogyakarta.

Denny Putra, Pratama, (2007). Euro-fuzzy, system pengendalian sudut pitch, turbin angin Teknik Fisika-FTI-ITS.

Eggleston, D. M. & Stoddard, F. S., (1987). Wind Turbine Engineering Design, Van Nostrand Reinhold, New York.

Hansen Morten, Larsen T., Sorensen P., (2005). Control Design for a Pitch – regulated, Variable Speed Wind Turbine, Riso National Laboratory Denmark.

Handayani, Sri Utami.2007. Tesis Karakteristik Daya dan Pola Aliran Turbin Angin Kecepatan Rendah dengan Winglet. UGM: Yogyakarta.

Himran, Syukri, 2006. Energi Angin, CV Bintang Lamumpatue, Makassar.

Johnson, Gary L. 2006. Wind Energy System. Manhattan : KS, 2006.

Musyafa A., A.Harika, I.M.Y.Negara, I. Robndi, Pitch Angle Control of Variable Low Rated Speed Wind Turbine Using sFuzzy Logic Control, International Journal Of Engineering & Technology IJET-IJENS Vol:10 No:05, October 2010.

Sterzinger G., Svreck Matt, (2004). Wind Turbine Development: Location of Manufacturing Activity, Renewable Energy Policy Project. Department of Energy US.

Ushiyama, I., Shimota, T. and Miura, Y. (1996), An Experimental Study of the Two-staged Wind Turbines, Renewable Energy, 9, (1-4), pp. 909-912.

www.mst.gadjamada.edu/dl/Kincir_Angin.pdf (02 Maret 2013, pukul 18:29).

http://www.scribd.com/doc/21369754/Teori-Momentum-Untuk-Turbin-Angin-Ideal (14 Maret 2013, Pukul 16:37)

PlumX Metrics

Published
2018-12-07
How to Cite
Bere, F., Koehuan, V., & Jasron, J. (2018). Analisis Performansi Turbin Angin Poros Horisontal Model Double Rotor Contra Rotating dengan Posisi Rotor Saling Berhimpitan. LONTAR Jurnal Teknik Mesin Undana, 2(1), 15-22. https://doi.org/10.35508/ljtmu.v2i1.481
Section
Articles

Most read articles by the same author(s)

Obs.: This plugin requires at least one statistics/report plugin to be enabled. If your statistics plugins provide more than one metric then please also select a main metric on the admin's site settings page and/or on the journal manager's settings pages.