Simulasi Termodinamika Pengaruh Temperatur Subcooling di Kondensor Terhadap Kinerja Cold Storage
Abstrak
The subcooling temperature in the condenser can affect the overall performance of the refrigeration system. One of the refrigeration systems that plays an important role in the cold chain of fishery products is cold storage. This paper discusses thermodynamic study of the effect of condenser subcooling temperatures on the performance of cold storage that operates based on a vapor compression refrigeration cycle based on the CoolPack software. The subcooling temperatures varied was 5 – 10 Kelvin and the system performance parameters analyzed were refrigerant mass flow rate, heat rejected in the condenser, compressor power and coefficient of performance. The results of this study indicate that as the subcooling temperature increases, the refrigerant mass flow rate decreases so that the compressor power and the rate of heat release in the condenser also decrease. Thus, the performance coefficient of cold storage will increase as the subcooling temperature increases.
##plugins.generic.usageStats.downloads##
Referensi
[2]. Servianus, Y. V., Dwinanto, M. M., dan Jafri, M., 2019, “Analisis Teoritis Pengaruh Temperatur Subcooling Terhadap Kinerja Batch Air Blast Freezer Menggunakan Software Coolselector®2”, Prosiding SAINSTEK IV, Kupang, 25 Oktober, 256 – 264.
[3]. Fongo, P. E. F., Dwinanto, M. M., dan Sanusi, A., 2019, “Pengaruh Temperatur Subcooling Kondensor Terhadap Kinerja Cold Storage Menggunakan Perangkat Lunak CoolPack 1.5”, Prosiding SAINSTEK IV, Kupang, 25 Oktober, 433 – 439.
[4]. Luan, F. F. R., Dwinanto, M. M., dan Tarigan, B. V., 2019, “Analisis Pengaruh Temperatur Superheat Terhadap Koefisien Kinerja Cold Storage Menggunakan Coolselector®2”, Prosiding SAINSTEK IV, Kupang, 25 Oktober, 222 – 230.
[5]. Pottker, G., and Hrnjak, P., 2015, “Effect of the condenser subcooling on the performance of vapor compression system”, International Journal of Refrigeration, Vol. 50, 156-164.
[6]. Hadya, B., 2016, ”Analysis of vapour compression refrigeration system with subcooling and superheating with three different refrigerants for air-conditioning application”, International Journal of Engineering Sciences and Research Technology, 70-77.
[7]. Karakurt, A. S., Gunes, U., and Ust, Y., 2016, ”Exergetic and economic analysis of subcooling and superheating effect on vapor compression refrigeration system”, Proceedings of the ASME 2016 Power Conference, June 26-30, 59492, 1-6.
[8]. Sasongko, M. N., 2017, “Unjuk kerja mesin pendingin kompresi uap pada beberapa variasi superheating dan subcooling”, SAINTEK II, E26-123 – E26-127.
[9]. Suparmin, P., Antono, V., and Nurhasanah, R., 2017. ”Effect degree of temperature subcooling in the performance of refrigeration with CFC, HFC, and hydrocarbons refrigerant”, MATEC Web of Conferences 101, 03002, 1-6.
[10]. Azzouzi, D., Kelkouli, M., and Amaryoucef, F., 2017, ”Parametric study of the wire-on-tube condenser subcooling effect on the performance of vapor compression refrigeration system”, Applied Thermal Engineering, Vol. 122, 528-534.
[11]. Jakobsen A, Rasmussen B. D., Skovrup M. J., and Andersen, S. E., “CoolPack–A Collection of Simulation Tools for Refrigeration”, Department of Energy Engineering, Technical University of Denmark (DTU), Denmark, 2001.
[12]. Sencan A., Selbas R., Kizilkan O., and Kalogiru S. A.,2006, “Thermodynamic analysis of subcooling and superheating effects of alternative refrigerants for vapour compression refrigeration cycles”, International Journal of Energy Research, Vol. 30, 323–347.
##submission.copyrightStatement##
##submission.license.cc.by-nc-nd4.footer##