SISTEM PENGATURAN MOTOR DC MENGGUNAKAN PROPOTIONAL IINTEGRAL DEREVATIVE (PID) KONTROLER

  • Nur Salim(1*)
    Universitas Nusa Cendana
  • (*) Corresponding Author
Keywords: PID Controllers, DC Motors

Abstract

This research aims to control the DC motor rotation using the control system using PID (Proportional Integral Derivative). To see the performance of PID controller, it will be compared to a DC motor using PI controller (Proportional Integral)). From the results of experiments that have been done indicate that the DC motor using PID controller when starting without load takes about 0.066 seconds. While the DC motor using PI controller takes about 2.345 seconds. At the time of granting the load, the DC motor using PID controller requires recovery time to reach the setpoint was 0.034 seconds. While for DC motor using PI controller requires recovery time to reach the setpoint is 0.411 seconds.

Downloads

Download data is not yet available.

Author Biography

Nur Salim, Universitas Nusa Cendana

Jurusan Teknik Elektro, Fakultas Sains dan Teknik, Universitas Nusa Cendana

References

Brilliant Adhi Prabowo, 2001. Pemodelan Sistem Kontrol Motor DC dengan Temperatur Udara sebagai Pemicu, jurnal informatika LIPI.

Handy Wicaksono, dkk. 1999. Kontrol PID Untuk PengaturanKecepatan Motor DC Dengan Metode Tuning Direct Synthesis.

H. LeHuy dan G. Sybille Help Matlab 7.4

PlumX Metrics

Published
2012-04-01
How to Cite
[1]
N. Salim, “SISTEM PENGATURAN MOTOR DC MENGGUNAKAN PROPOTIONAL IINTEGRAL DEREVATIVE (PID) KONTROLER”, JME, vol. 1, no. 1, pp. 22 - 27, Apr. 2012.