PENGUJIAN INTENSITAS CAHAYA PADA RUANG LABORATORIUM KOMPUTER FAKULTAS SAINS DAN TEKNIK (FST) UNDANA MENGGUNAKAN CALCULUX V.5.0

  • Nursalim Nursalim(1*)
    Universitas Nusa Cendana
  • Sri Kurniati(2)
    Universitas Nusa Cendana
  • Aloysius L. Kabelen(3)
    Universitas Nusa Cendana
  • (*) Corresponding Author
Keywords: Intensity Lighting, Calculux v5.0, Laboratory

Abstract

This study aims to determine the large intensity lighting (Eaverage) based benchmark Indonesian National Standard (SNI) at the Computer Laboratory of the Faculty of Science and Engineering (FST) is 500 Lux by of direct measurement, data analysis and simulation using software Calculux. Based on the results of the measurement, calculation and analysis of large value obtained Eaverage of 304.398 lux, so it can be seen that the laboratory has not reached the recommended ISO standards for laboratories. It is necessary for the simulation to achieve compliance in accordance with the ISO using Calculux v5.0. After performing simulations to obtain the fulfillment of the ISO standard, showed that the amount of light on a computer lab is 8 units (304 398 lux) should be increased to 10 pieces with the same kind of light, so that it can reach the standards set, which is equal to 500 lux.

Downloads

Download data is not yet available.

Author Biographies

Nursalim Nursalim, Universitas Nusa Cendana

Jurusan Teknik Elektro, Fakultas Sains dan Teknik, Universitas Nusa Cendana,

Sri Kurniati, Universitas Nusa Cendana

Jurusan Teknik Elektro, Fakultas Sains dan Teknik, Universitas Nusa Cendana

Aloysius L. Kabelen, Universitas Nusa Cendana

Jurusan Teknik Elektro, Fakultas Sains dan Teknik, Universitas Nusa Cendana

References

Anonim. Manual Calculux Indoor.

Farid Khusnul Mujib, dan Andi Rahmadiansah. Desain Pencahayaan Lapangan Bulu Tangkis Indoor ITS. Jurnal Teknik Pomits Vol. 1, No. 1. 2012. http://www. digilib.its.ac.id. diakses 5 maret 2013.

Anonim. SNI 03-6575-2001 Tata Cara Perancangan Sistem Pencahayaan Buatan Pada Bangunan Gedung.

Anonim. SNI-16 7062 2004 Pengukuran Intensitas Penerangan ditempat Kerja.

PlumX Metrics

Published
2013-01-22
How to Cite
[1]
N. Nursalim, S. Kurniati, and A. Kabelen, “PENGUJIAN INTENSITAS CAHAYA PADA RUANG LABORATORIUM KOMPUTER FAKULTAS SAINS DAN TEKNIK (FST) UNDANA MENGGUNAKAN CALCULUX V.5.0”, JME, vol. 1, no. 3, pp. 93 - 96, Jan. 2013.
Section
Articles