Abstract

The distribution of the shear wall horizontally influences the drift. This study was conducted to determine the relationship between the horizontally mass distribution of shear walls and high-rise buildings’ drift. The model analyzed was a rectangular building with 40 floors of 20 m x 20 m. The model consists of 4 variations, namely G1, G2, G3, and G4 models. The analysis was carried out based on SNI - 1726 - 2019 regarding The Procedures of Earthquake Resistance Planning for Building and Non-Building Structures and using SAP 2000 software. The analysis results revealed that horizontal shear wall mass distribution influences the structural deviation due to earthquake loads. Shear walls distributed side by side are more efficient than shear walls distributed spatially.

Downloads

Download data is not yet available.

References

(BSN), Badan Standarisasi Nasional. 2003. Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung Dan Non Gedung. Jakarta: Badan Standarisasi Nasional.
(BSN), Badan Standarisasi Nasional. 2019. Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung Dan Nongedung (SNI 1726:2019). Jakarta: Badan Standarisasi Nasional.
(BSN), Badan Standarisasi Nasional. 2019. Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung dan Non Gedung (SNI 2847:2019). Jakarta: Badan Standarisasi Nasional.

(NFPA), National Fire Protection Association. 2011. High-Rise Building Fires. National Fire Protection Association Fire Analysis and Research Division. https://www.nfpa.org/Assets/files/AboutTheCodes/70E/NEC_StyleManual_2011.pdf.
Alwi, Irbar Darmansyah. Modul SAP Dengan Tutorial Bahasa Indonesia. https://www.academia.edu/30097325/Modul SAP Dengan_Tutorial Bahasa Indonesia (accessed June 17, 2021)
High-rise Building (ESN 18727). “Emporis Standard.” https://www.emporis.com/building/standard/3/high-rise-building (accessed June 17, 2021).
Kuningsih,T.W.2011.“Simpangan (Driff) Akibat Gaya gempa.” https://triwahyukuningsih.wordpress.com/2011/05/13/(accessed September 30, 2021).
Mulyono. 2000. Petunjuk Standarisasi Desain Gedung Bertingkat. Bandung: Ganeca Exact.
PPIUG.1983.“Peraturan Pembebanan Indonesia Untuk Gedung.” Stensil, Bandung.
Sansujaya, Evantianus, Jusuf J.S. Pah, and I Made Udiana. 2021. “Studi Kefektifan Dinding Geser Pada Bangunan Tingkat Tinggi Dalam Mengurangi Simpangan Struktur.” Jurnal Forum Teknik Sipil (J-ForTekS) 1(1): 24–34.
Suparman. 2015. Penyelidikan Tanah Kampus Undana. Kupang.